Air Man, Air Maze, Amoco, Atlas Copco, Balston, Bauer, Becker, Busch, Campbell-Hausfield, Canadian Air, Champion, Chevron, Chicago-Pneumatic, Chinook, Comp air, Comp air-Kellogg, Conoco, Consler, Cooper, CPI Engineering, CPI Engineering (Lubrizol), Curtis, Davey, Deltech, Dollinger, Dresser-Rand, Driltech, Dubbois, Dunham Bush, Emglo, Exxon, Filerite, Finite, Flottman, Frick, Furakawa, Gardner-Denver, General Pneumatics, Gordon Schmidt, Grimmer Schmidt, Hankison, Hatco, Headline, Hitachi, Hokeutsu, Huls-America, Hydra Screw, Hydrovane, Inervac, Ingersoll-Rand, Jaeger, Jonell, Joy, Kaeser, Kellogg, Kemp, Keystone, Kinney Vacuum, Kobe, Leroi, Leybold, Lubricant Engineering, Mann, Mark, Mattei, Mechanequip, Microfiltration, Mitsuiseki, Mobil Oil, Molub-Alloy, Multiquip, Mycom, Norgren, Numatics, Onan, Pacer, Palatek, Pall, Parker, Peco, Pennzoil, Pioneer, Pneumatch, Quincy, Quincy Northwest\Rogers, Reco, Redmaz, Reedrill, Reichdrill, Reitschle, Rotary Aire, Royal Purple, Sargent Welch, Saylor-Beall, Schramm, Shell Oil, Solberg, Stoddard, Stokes, Sullair, Sullivan, Syn-Flo, Tamrock, Technolab, Texaco, Travaini Pump, Ultra Air, Ultra Filter, Ultrachem, Universal, Van Air, Vilter, Webster, Wilkerson, Worthington, Zander, Zeks
Filtros (PFI in Espanol) -     Order A Free Pricebook    September 3, 2010, 10:44 am


Main Page
Air & Oil Filters
Separators & Coalescers
Cross References For Manufacturers
Contact Us Parts List Separator Sizing Chart

For a free quote, call toll-free - (USA)
800-866-2959, or fax your quote to
972-247-3264, or Contact Us.

FILTER ELEMENT CLEANING INSTRUCTIONS



CLEAN BY HAND WASHING

  • Soak and agitate element in a warm water & mild detergent solution.
  • Allow adequate time for the element to air dry. (24 hours minimum)
  • Do not install a damp element. This will cause higher initial pressure loss & rapid dirt loading.
  • The dry element is ready to be re-used.

CLEAN BY COMPRESSED AIR

  • Using approximately 100 PSI, direct air flow at inside of element towards pleats.
  • Blow off the outside of the element directing the air flow down to avoid embedding dirt in the media.
  • Blow off the inside again to remove any dirt that might be on the clean side of the element.
  • The element is ready to be re-used.

CLEANING BY VACUUM

  • Remove element from housing.
  • Vacuum from dirty side only, using a vacuum of approximately 40" w.c.
  • A crevice attachment is recommended.
  • The element is ready to be re-used.

CLEANING BY HAND

  • Remove element from housing.
  • Hold element down with one hand & move other hand across the fins in a strumming motion. This action will dislodge most of the dirt.
  • The element is ready to be re-used.
The Best Reason to use a Synthetic Felt Media is Re-Usability. Typically, customers can expect these filters to be re-washed 6-8 times, some have even reused these 10 times. Take a look at the Differences between Paper and Synthetic Media Air Filters





Disclaimer: We are an Aftermarket Supplier, we are not in any way affiliated with any of the OEM's.
Manufacturers Names and Part numbers are for Reference Purposes only.
We are selling Performance Filtration Brand Only.


© 2000-2010 Performance Filtration, Inc.
2110 Hutton Dr, Ste 110
Carrollton, TX 75006 USA
800-866-2959(t)
972-247-3220(p)
972-247-3264(f)